Connections and settings
Sampling Frequency settings
Set the sampling frequency of the VS-2400CD and ADAT device to the same setting (48 kHz).
Master Clock settings
You'll also need to set the Master Clock for the ADAT device. For details on this setting, refer to the owner's
manual for the ADAT device.
Synchronization settings
Set the VS-2400CD's parameters as follows.
MIDI PARAMETER screen
SysEx. Rx. Sw.On
MMC MODE..SLAVE
MMC SOURCER-BUS
SYNC PARAMETER screen
SYNC MODE.EXT
EXT SYNC SOURCER-BUS
FRAME RATE..................... Same setting as the software.*
BRC settings
1
Press [EDIT] [GEN SYNC] [GEN SYNC].
The screen will indicate “Generate Sync.”
2
Use [][] to select “MIDI: MTC,” and press [EDIT].
[EDIT] will go dark.
3
Press [GEN SYNC].
[GEN SYNC] will light, and the BRC will output MTC.
Master clock device VS-2400CD setting
DIF-AT24
MASTER CLK switch
VS-2400CD
PROJECT PARAMETER screen
MASTER CLOCL................INT
R-BUS
ADAT device
PROJECT PARAMETER screen
MASTER CLOCL................R-BUS
ADAT