The playback pitch is strange
The Vari-Pitch function is turned on (the VARI
PITCH indicator is lit).
The time compression/expansion function is being
used (Owner’s Manual p. 90).
Disk drive problems
The internal hard disk is not being
recognized
The hard disk has not been installed correctly.
“IDE Drive” is set to “Off” (Owner’s Manual p. 189).
The “Partition” settings are not right.
When a high-capacity hard disk is installed in the
VS-1680, we recommend setting the partition size to
“2000MB.”
The Zip drive is not recognized
The Zip drive is not connected correctly.
The same device ID number is assigned to two or
more SCSI devices (Zip drives , CD-R drives, etc.).
The Zip drive has not been initialized (Owner’s
Manual p. 111).
No Zip disk is inserted in the drive.
When switching Zip disks, be sure to select the
newly inserted disk as the current drive.
An archives copy Zip disk is inserted.
Internal Effects
Effects cannot be used
The VS8F-2 has not been installed correctly.
Only one VS8F-2 has been installed (when EFFECT B
cannot be used).
You are attempting to select the algorithm for
Reverb, Gated Reverb, Vocoder 2, or Voice
Transformer with EFX2 or EFX4.
You are attempting to select the algorithm for
Vocoder 2 or Voice Transformer with EFX1 or EFX3
(p. 105, 106).
CD-R Drive Problems
The CD-R drive is not being recognized
The CD-R drive is not connected correctly.
The same device ID number is assigned to two or
more SCSI devices (Zip drives , CD-R drives, etc.).
No CD-R disc is inserted in the drive.
A CD-R drive that is not designated by Roland.
Cannot write to CD-R discs
The song’s sample rate is set to something other than
44.1 kHz (Owner’s Manual p. 58).
No IDE hard disk is installed.
The internal IDE hard disk does not have sufficient
free disk space (Owner’s Manual p. 169).
The CD-R disc does not have sufficient free space.
You are trying to write to a commercial CD software
disc.
You are trying to write to a CD-R disc that has been
finalized.
MIDI Devices
With the VS-1680 as master, the
sequencer does not respond to com-
mands
The MIDI cable is not connected correctly.
The MIDI cable is broken.
The MIDI Thru switch is not set to “Out” (Owner’s
Manual p. 129).
“Sync Gen.” (the sync generator) is not set to the
appropriate synchronization method (MTC, MIDI
Clock, Sync Track) (Owner’s Manual p. 133).
The EXT indicator is blinking (“Sync Source” is set
to “EXT”).
The two devices are not set to the same type of MTC
(during MTC synchronization).
The MIDI clock data has not been recorded on the
sync track (if you are using the sync track for syn-
chronization).
The settings of the MIDI sequencer are not correct.
The MIDI sequencer is not ready to playback.