Description:
When sheets are fed automatically, two or more sheets may be fed inadvertently into a processing machine. This can damage tools, cause halt in
production or result in expensive repairs. The double sheet detector E10 can reliably prevent this from occuring.
In addition to the connection of one sensor an option is available to connect four sensors of the same type (E10 4P). Sensor switching is accomplished
either separately sequentially via the PLC or via program selection. In the latter configuration the system is also used for Hidden Parts Detection.
Function:
The double sheet detector is based on the electromagnetic principle. It monitors ferromagnetic sheets with one-sided contact and exerts force during
the monitoring process only. A change of the sheet thickness results in a change of induction. The system calculates the sheet thickness from this
change. Corresponding to the pre-set limits 0-sheet, 1-sheet or 2-sheets signals are generated.
One sensor can be connected to the control unit (type E10) or up to 4 sensors (type E10 4P). The control unit is available in 3 versions A, B and C.
Memory and signal inputs:
Version A: Memory for 255 parameter sets (thicknesses). Programming and addressing
by push buttons. Measurement start via control input
Version B: Memory for 255 parameter sets (thicknesses). Programming by push buttons
Addressing with 9 respectively 11 data inputs opto coupled 24 VDC with joint common
Version C: Memory for 255 parameter sets (thicknesses). Programming by push buttons
Addressing with 9 respectively 11 data inputs opto coupled 24 VDC with joint common
1 opto coupled RS 232 interface for bidirectional data communication with a PLC or a PC
Signal outputs Relay version (Version A and B): Optocoupled version (Version B and C):
Signal outputs: dry two way contacts Emitter and collector
Maximum switching voltage: 250 V AC 50 V DC
Maximum switching current: 1 A 150 mA
Maximum switching power: 240 W / 200 VA 100 mW
Sensors: P 36 GS P 42 GS P 75 GS
DOUBLE SHEET DETECTOR E10
Sensor cable
DOUBLE SHEET DETECTOR E10
Sensor Diagrams: Systems reaction time with upper switching limits (UL) at 150%, 120% and 100% of nominal sheet thickness
P 36 GS P 42 GS
Spring loaded sensor bracket with vacuum cup SHS
for sensors P 36 GS and P 42 GS
(also available without vacuum cup as type SH...GS)
P 75 GS
optional rigth angle receptacle
300
or custom made
57
Lift max. 65
min. 25
movable
Clampin
g
bracket SHK
fixed
110
Sprin
g
loaded sensor bracket
Sensor
Cup
6
5
6
98
ø25
25
94
M8
40
Measurement
on
001-1 N=1.00 on
0.80<=1.02=>1.20
Program
number
Selected sensor (1-4)
Nominal thickness
001-1 N=1.00 on
0.80<=1.02=>1.20
Measuring
value
Upper limit
Lower limit
LED buttons
Function of the LED buttons
Function of the LED´s
Technical Data:
Operating voltage: 24V DC ± 4V
Power consumption: < 17 W
Enclosure meets: IP 65
Ambient temperature: 0 - 50
o
C
(32
o
to 122
o
F)
Weight: approx. 1,5 kg
(3.3 lb)
Dimensions
Unit E10: Unit E10 4P
Width: 140 mm 180 mm
Height: 140 mm 140 mm
Depth: 71 mm 71 mm
Order data:
Control unit for the connection of one sensor:
E 10 A - R: Manual operation Relay-Version
E 10 B - R: Control via PLC Relay-Version
E 10 B - O: Control via PLC Opto coupler-Version
E 10 C - O: Download via PLC Opto coupler-Version
Control unit for the connection of up to four sensors:
E 10-4P-B - R: Control via PLC Relay-Version
E 10-4P-B - O: Control via PLC Opto coupler-Version
E 10-4P-C - O: Download via PLC Opto coupler-Version
Control unit with central sensor cable
for the connection of up to four sensors
E 10-4P-B - R - Z: Control via PLC Relay-Version
E 10-4P-B - O - Z: Control via PLC Opto coupler-Version
E 10-4P-C - O - Z: Download via PLC Opto coupler-Version
Sensors:
P 36 GS Electro-magnet up to 2,5 mm single sheet thickness
(The sensor P 36 GS should only be used in case of
confined space situations. The standard sensor
should be P 42 GS)
P 42 GS Electro-magnet up to 4,0 mm single sheet thickness
P 75 GS Electro-magnet up to 6,0 mm single sheet thickness
Sensor cable:
CPS - 5 - G Oil:Straigth receptacle (Standard cable length 5m)
CPS - .. - G Oil:Straigth receptacle (Cable up to 25m made to order;
for longer cables enquire)
CPS - 5 - W Oil:Rigth angle receptacle (Standard cable length 5m)
CPS - .. - W Oil:Rigth angle receptacle (Cable up to 25m made to
order; for longer cables enquire)
Special accessoires:
SH 36 GS: Spring loaded sensor bracket for P 36 GS
SH 42 GS: " P 42 GS
SHS 36 GS: " with vacuum cup for P 36 GS
SHS 42 GS: " with vacuum cup for P 42 GS
SHK: Clamping bracket
2395110: Rubber lips for vacuum suction cup
PWS E10 Program selection box
RPP: Software (DOS) for parameter back up (Version C only)
Plug width 30 mm
SW90
ø30
21
30
Necessary space
for sensor plug
connection: 75mm
31
72
14
68,5
M75x1,5