If a problem is found, the following error display will appear.
DEVICE (Error content)
LCD display Faulty content
Err PROGRAM ROM Program (flush or mask ROM) fault
Err DRAM Work DRAM read/write fault
Err Wave ROM Wave ROM data content fault
Err RAM for DSP DSP RAM read/write fault
Err EEPROM EEPROM read/write fault
Err DATA ROM DATA ROM data content fault
Err DATA TYPE DATA ROM type check fault
If an error display appears, press the [Function] button to advance the test mode.
If the test results were OK, the following display will appear.
Press the [Function] button to advance to item 3.
3. Button and LED check
All LEDs will light, and the following display will appear.
Note: If you wish to check item 3, do not press the [Function] button first.
If you press the [Function] button first, you will advance to item 4.
Once you begin the checking process for this test item, it is not possible to advance to the next item before testing all buttons.
Press the following buttons, and confirm that a sound is heard and that the button LED goes dark.
[piano] [E.piano] [Harpsi] [Vibes] [Organ] [Strings] [Choir] [GSTones] [Reverb] [Chorus][Pianist][Split] [Transpose] [Track R] [Track 1]
[Track 2] [Play] [Rec] [Function]
Press the following button twice, and confirm that a sound is heard and that the button LED changes from orange to green to dark.
[Key Touch]
Press the following button twice, and confirm that a sound is heard and that the button LED changes from orange to green to dark, and that
the button LED goes dark the second time.