8. Indicator adjustment
9. Cam adjustment
10. Dampers
To adjust the indicator, take off front cover and pull the indicator
upwards until it comes off the Allen screw.
Before installing the indicator make sure that the Allen screw is
tightened. Press the indicator on the screw and adjust it by rotating
clockwise to desired position.
With the cover and indicator removed, loosen the screw 1 and turn the
cam locking nut 2 counterclockwise until the cam loosens. Adjust the
cam 3 as desired making sure that the ball bearing 4 always is riding
on an active lobe on the cam. To secure the cam, make sure that screw
1 is backed out from the locking nut 2 then finger tighten the locking
nut and tighten screw 1. Install and adjust the indicator and reinstall
cover.
The standard built in dampers 5
located on the connecting block prov-
ide a simple means of adjusting the
actuator travel speed.
For maximum actuator travel speed
dampers shall be adjusted to mini-
mum damping position. (Fig).
Double acting actuators – adjust
only OUTLET damper, set SUPPLY
damper in minimum damping posi-
tion.
Single acting actuators – adjust both
dampers for desired operation.
3
1
correct
incorrect
5
2
4
1-2 mm (1/16")